Blenheim Court, SL6 1AQ, PulsaCoil A-Class

We have created this PulsaCoil A-Class repair Case Study page to enable you to see before and after images of a typical repair. Blenheim Court, SL6 1AQ, PulsaCoil A-Class Repair Case Study features a … Miss H contacted us as she was not getting hot water from her PulsaCoil A-Class and required and engineers visit. Miss H is just one example of the many customers that we work for in this area.

Blenheim Court, SL6 1AQ, PulsaCoil A-Class Repair Case Study

Miss H first called The Plumbing Group when she began experiencing some issues with her PulsaCoil A Class. An engineer was able to get out to her property on the same day to take a look at the boiler.

Once an engineer had arrived, he completed a thorough check of the unit. He found that the problem was with the overheat sensor. It had failed, as a result of the failure it was not allowing the unit to heat-up. He also found that the on-peak relay and failed and had burnt out the cabling.

The engineer replaced the overheat sensor. Then he replaced the relay and the damaged wiring in order to repair the unit for Miss H. Following the repair our engineer then carried out further tests to ensure that everything was working correctly. The engineer made sure to keep Miss H fully informed during this process.

The repair was carried out within 1 hour and Miss H was extremely happy to have hot water later on that evening.